MiEV Tools
Tool Name:
Gloves Set, Electric Insulated
Required for high voltage repair/diagnosis.Store tool in Mitsubishi "i" bag 561987.
Important: Rubber insulating gloves include a stamped date indicating when the rubber insulating gloves were "originally or last tested electrically." Rubber insulating gloves must be re-tested electrically by a certified lab 6 months after first use. The lab will re-stamp the gloves with the new "tested" date.
The following in-dealership guidelines for the use of High Voltage Safety Gloves must be managed by the dealership:
New gloves and sleeves are marked with the date of manufacture/electrical test and are acceptable for use 12 months from that date.
If new gloves are first used within 12 months of the manufacture/electrical test date, re-certification must occur 6 months from first use. The first use date should be recorded.
If the first use date is not known, the gloves/sleeves must be retested 6 months from the electrical test date stamped on the glove/sleeve.
All gloves must be inspected by the user for damage prior to each use. For more information on how and where to get your High Voltage Safety Gloves re-certified, visit the following site to find an accredited laboratory: http://www.nail4pet.org/
A purchase of new kit/gloves is an alternative to re-certification.